1. Introduction

RK7305Y medical grounding resistance tester is used to measure the ground (earth) resistance inside the electrical equipment, which reflects the (contact) resistance between the exposed conductive parts of the electrical equipment and the general grounding terminal of the electrical equipment. This equipment can meet the test requirements of IEC60335-1 and IEC60601.


2. Application

1). Household appliances: TV sets, refrigerators, air conditioners, washing machines, dehumidifiers, electric blankets, chargers, etc.

2). Transformers: oscilloscopes, signal generators, DC power supplies, switching power supplies and other complete machines

3). Medical equipment: all kinds of new medical instruments and medical supporting instruments, heart monitoring, medical imaging, biochemical analysis instruments, sphygmomanometers and thermometers and other home medical equipment

4). Lighting industry: ballasts, road lights, stage lights, portable lights and other lamps

5). New energy vehicles: electric vehicle battery pack connection bridge, battery connection resistor

6). Electronic components: diodes, triodes, high-voltage silicon stacks, various electronic transformers, connectors, high-voltage electrical appliances

7). Electric heating appliances: electric drills, pistol drills, cutting machines, grinding machines, electric welding machines, etc..


3. Parameter

Model

RK7305Y

Input power

50/60Hz±5%, 115/230VAC±10%

Output current

3-30A (AC), constant curernt source, resolution: 0.1A/step, accuracy: ± (2% setting value+0.02A)

Output voltage

6V (AC), Max (measured in open circuit)

Output frequency

50Hz/60Hz

Resistance range

0-120mΩ (>10A)/1-510mΩ(10A), resolution: 1mΩ/step

Accuracy: ± (2% reading value+1 digit)

Zero adjustment

Max 100mΩ, resolution: 1mΩ/step, accuracy: ± (2% reading value+1 digit)

Upper limit setting

Range: 0-510mΩ, resolution: 1mΩ/step, accuracy: ± (2% reading value+1 digit)

Test time

Range: 0.5-599.9s (0=continuous test)

Control interface

Input: TEST, RESET, WITHSTAND PROCESSING

Ouput: PASS, FAIL, TEST-IN PROCESS

Test result output method

Buzzer, LCD display, control interface status output

No. of memory group

5 groups

Display

LCD screen

Working condition

0-40℃, ≤75% R.H.

Dimension

D410mm*W290mm*H100mm

Accessories

Power cable, test wire

Safety lock

Equipped with keyboard lock function

Weight

8.7kg

Fuse

3.15A