IEC60238 Lampholders Normal Operation Test Apparatus

IEC60238 Lampholders Normal Operation Test Apparatus

share
  • Detail
  • Parameters

Lampholders Normal Operation Test Apparatus

1.Introduction

The normal operation test apparatus is designed according to BS EN60238 clause 18 and figure 4, and IEC60238-2017 clause 19 and figure 4.   It is to verify if excessive wear or other harmful will show in lampholders during normal use.

The specimen shall be placed in the test apparatus, a corresponding test cap (E14, E27, E40) shall be screwed in and out with a torque of 0-3Nm for 100 times at a rate of 15 times/min, after reaches the specified number of tests, it will automatically stop. After the test, the specimen shall show: 1). no wear impairing its operation; 2). no damage impairing protection against electric shock; 3). no loosening of electrical contacts; 4). no loosening of the connection between shell and dome; 5). no loosening of the set screw locking the threaded entry.


2.Parameters

Control mode

PLC+touch screen

Number of working station

1

Drive mode

Motor-driven

Test times

0-999999 (settable)

Test speed

15 times/min

Test caps

Test caps E14, E27, E40 (as per IEC60238:2017 figure 13, figure 14, figure 15) for torque test

Torque range

0.1-3Nm (0.4Nm for candle lampholder E14, 1Nm for lampholder E14, 1.5N for lampholder E27, 3N for lampholder E40)

Working Power

AC220V/50Hz


Description
The Normal Operation test Apparatus is designed according to BS EN60238 clause 18 and figure 4, and IEC60238-2011 clause 18
Model
PG-NOA